Why does the power plant desulfurization foam?
With the rapid
development of industry and the importance of the country and people to
environmental protection, power plant desulfurization process has become an
important part of power plant production.
The flue gas
desulfurization process of normal power plants can be divided into three
categories: wet method, dry method and semi-dry method according to the state
of desulfurizer and desulfurization reaction product. At present, the flue gas
desulfurization technology is dominated by the wet desulfurization process, and
the dry and semi-dry desulfurization processes are also under development.
Since the
desulfurization agent is used for flue gas desulfurization in thermal power
plants, and the desulfurizing agent is alcohol, the practical and common
silicone defoaming agent is used to obtain the foaming effect of the absorption
tower slurry of the desulfurization device through practical experiments and
laboratory test foam data. The bubble effect is not obvious. We specialize in
desulfurization defoamers specially designed for the control of foam in amine
treatment and diol dehydration units;
It has the following characteristics:
Ø Quick
defoaming: This product is especially effective when the foam forms quickly in
the absorption tower or requires rapid defoaming.
Ø Excellent
stability and durability: After a while, the salt concentration in the amine
treatment and diol dehydration unit will reach the highest level. TSA-7133
desulfurization defoamer is very stable under these conditions. In addition, in
order to maintain good line control, a lower amount of defoamer should be used,
while also reducing costs and the possibility of fouling and clogging. In
addition, since the product is easily dispersed in water and compatible with
the diol, the moisture in the antifoam emulsion is not easily removed by the
presence of the diol, so that the effectiveness of the antifoaming agent can be
achieved. Keep it for a longer time.
Ø Excellent
high temperature stability - Due to the excellent dispersibility of INVELY-5300
desulfurization defoamer, such products do not deposit on heat exchangers like
many other defoamers. They tend to be well dispersed in the amine or diol
solution and finally separated by filtration.
Ø Easy to
dilute and use the simple addition of water and a slight agitation to dilute
the INVELY-5300 desulfurization antifoam antifoam emulsion to the desired
concentration. Pumping these diluted emulsions is very easy due to the reduced
viscosity after dilution.
Ø Reduce
heat exchanger blockage and dirt thermal resistance - potentially reducing
equipment maintenance.
Ø Low
concentration can effectively meet foam control –INVELY-5300 desulfurization defoamer is 2-3 times more
effective than other defoamers used in gas processing units.
Defoaming process foaming reasons
During the
operation of the desulfurization device, the absorption tower slurry may be
foamed due to some factors, resulting in overflow of the absorption tower.
These factors may be:
(1) Imported flue
gas dust exceeds the standard, if it contains a large amount of inert
substances
(2) The coal
quality is not good, the boiler is not fully burned or the boiler is oiled to
make the imported flue gas contain oil.
(3) The limestone
contains an excess of MgO, and the excess of MgO not only affects the
desulfurization efficiency but also reacts with the sulfate ion.
(4) The increase of
heavy metal ions in the absorption tower slurry causes an increase in the
surface tension of the slurry.
(5) In addition, it
is also necessary to pay attention to the parameters of the desulfurization
system process water quality should be within the scope of the design,
otherwise it will lead to absorption tower slurry bubbles.